Home › Applications › Energy & power monitoring
Energy & Power MonitoringEvery multi-function meter on one RS-485 line, logged through outages, delivered to your energy dashboard
Daisy-chain your Modbus energy meters and one gateway reads volts, amps, power factor, kW and kWh from up to 64 of them (32 on the LITE series). Every reading is time-stamped, kept through a network drop and delivered to your server or platform over 4G, Ethernet or Wi-Fi.
- Up to 64 meters per gateway
- One packet per meter
- Store & forward
- Two servers at once
- PF / kW alerts by SMS
Watch it work
click a step to hold it- Step 1 of 5The gateway polls each meter in turn on the RS-485 line — Modbus RTU, one slave ID at a time.
- Step 2 of 5Each reading is stamped with the gateway's clock and logged — one packet per meter when you bill per meter, or all meters in one.
- Step 3 of 5The packets go to two servers at once: MQTT to the energy dashboard, HTTP to the ERP — each with its own packet format.
- Step 4 of 5The motor meter's power factor falls below 0.85. An edge trigger fires once on the crossing and texts the maintenance phone from the gateway's own SIM.
- Step 5 of 5If the network drops, readings keep logging. When it returns they go out oldest first, with their original time stamps — the dashboard fills in.
What connects to the gateway
What the gateway does here
Which gateway fits
open a model for its full specificationBeing straight about it
Questions
How many energy meters can one gateway read?
Up to 64 on the PRO and MAX series and up to 32 on the LITE series, on one RS-485 line. The WT460M and WT600M can poll Modbus TCP meters on the LAN as well, within the same count. The register budget is 3,000 words on PRO and MAX and 1,800 on LITE.
Which energy meter brands are supported?
Any meter that speaks Modbus RTU — or Modbus TCP on the WT460M and WT600M — and publishes its register map. The map is loaded into the gateway's Modbus database during configuration. Tell us the make and model and we will confirm before you order.
Can it read the utility's DLMS smart meter?
Not directly: a DLMS / IS 15959 billing meter does not speak Modbus. Put a WT50C DLMS to Modbus converter on the meter's communication port and the gateway polls the WT50C on RS-485 like any other Modbus meter.
Can each tenant be billed from its own meter?
Yes. With event packing set to one packet per slave ID, every meter's readings travel as their own record with the slave ID in it, so your billing system can split them without guessing.
What happens to the readings if the internet drops?
They are kept in the gateway's flash log — up to 17,500 records per server — and sent oldest first, with their original time stamps, once the link returns.
Can it send to our dashboard and our ERP at the same time?
On the PRO and MAX series, yes: two servers at once, each with its own protocol (TCP, HTTP or MQTT) and its own packet format. The LITE series sends to one server.
Can it alert us when the power factor drops?
Yes, on the PRO and MAX series. An edge trigger on the power-factor register fires when the value crosses your set point and can send an SMS (on the 4G models) or switch the relay. It fires once on the crossing, not again and again while the value stays low.