If you are searching for an "ADAM-4017 alternative", the reason is usually not the module. It is that an imported part is costed against the dollar and carries duty you cannot fix at quotation time, that the delivered date is not yours to control, and that you would rather work through a register map with the engineering team in your own working hours.

Wiman designs and builds RS485 Modbus RTU I/O cards in Chennai — WT30i, WT36i and WT32i — quoted and invoiced in rupees, built on our own line, and changeable at the volumes an Indian OEM actually orders. This page is written to be useful rather than flattering: our real published specs, what we will and will not claim, and an honest section on where Advantech's ADAM range is the better buy.

What you get by building it here

Priced and invoiced in rupees, start to finishAn imported module is quoted against USD/INR and then carries customs duty, IGST and the social welfare surcharge, so the delivered cost can move between the quotation and the purchase order. Our WT30i, WT36i and WT32i are quoted in INR and invoiced in INR. The number in your BOM on the day you cost the panel is the number you pay, which matters most on a plant with twenty or forty I/O nodes where a per-channel difference compounds across the whole job.
Built in Chennai — the lead time is ours to answer forThese cards are manufactured on our own line, so stock and build slots are something we control and can commit to on a call, with no customs clearance step and no inland freight from a port. If a commissioning date moves, ask us: we will give you a date for your quantity that we are willing to be held to, and if we cannot hit it we will say so before you raise the PO.
You talk to the people who wrote the firmwareYou get an application engineer in Indian working hours who will open your Modbus map with you, look at your register addressing and scaling, and — for a plant or an OEM line — come to site. When something needs a firmware change to work in your process, the conversation is with the person who can make that change.
Channel mix, terminals and private label at Indian OEM volumesWe build variants rather than asking you to pick the nearest standard part from ours. A different mix of voltage, current and digital channels, a terminal arrangement that suits your existing wiring loom, your brand on the front panel, your part number on the label — all of it is normal work for us at the order sizes an Indian machine builder or panel shop typically places. Tell us the channel mix you actually need and we will quote it.
Firmware behaviour tuned to your process, including the register mapOne of the more expensive parts of changing an I/O vendor is often not the hardware — it is re-tagging a SCADA database that already has thousands of points in it. We can lay our register map out to match the addressing your system already expects, and adjust behaviour such as scaling, engineering-unit conversion or the watchdog action so the module fits the plant instead of the plant fitting the module. How much of that is a configuration change and how much is a firmware build depends on the request, so let us scope it before you plan around it. As shipped, the WT32i already exposes a watchdog that is configurable over Modbus.
Commission with any Modbus master — no vendor utility, no Windows laptopOur cards are plain RS485 Modbus RTU devices. Commissioning is register reads and writes, so any Modbus master works — a Linux edge gateway, a Python script in your CI, a browser tool, or your existing SCADA. Our WIMNET Modbus Scanner will discover slave IDs, sweep register ranges and show raw RX/TX hex with timing, and there is a live demo of it on this site. Our browser-based Modbus hex converter is free to use and decodes Int, UInt and Float across ABCD/BADC/CDAB/DCBA byte orders. There is no licence or dongle attached to the hardware and nothing ties you to one operating system.
Local content for Make-in-India tender scoringIndian public procurement can give preference to bids meeting local-content thresholds under the Preference to Make in India policy, depending on how the individual tender is framed. A module designed and manufactured in Chennai contributes to your local-content declaration in a way an imported part cannot, regardless of the imported part's technical merit. The calculation and the declaration remain yours to make; we will supply what we can to support them. If you are bidding a tender scored on local content, this is worth a conversation before you fix your BOM.
One supplier for the I/O and the gateway above itThese cards sit on the same RS485 bus as our gateways, so the I/O, the Modbus master and the uplink come from one engineering team with one support contact. If a reading looks wrong at the server, the same person can look at the register on the card and the packet on the wire. There is no vendor boundary running through the middle of the problem.
We will tell you what we have tested and what we have notWe do not publish a number we cannot produce a test record for, and we will not describe our card as a drop-in replacement for anyone's part unless we have physically checked the register map, terminal pinout, power range and mounting against it and can hand you that record. If you send us the model you are replacing and your configuration, we will run the comparison and give you the result — including the cases where the answer is that our card is not the right fit.

Our published specifications

Every figure below is our own, taken from the product datasheet. We do not publish competitor specifications here — check theirs against their current datasheet and compare directly.

ItemWimanNotes
Analog voltage inputsWT30i: 4 × 0–10 V · WT36i: 6 × 0–10 V · WT32i: 2 × 0–10 VFrom our published product data. The WT36i carries the highest analog-channel count of the three cards.
Current inputsWT30i: 2 × 4–20 mA · WT36i: 6 × 0/4–20 mA · WT32i: 2 × 4–20 mAThe WT36i current inputs are listed as 0/4–20 mA. Confirm the exact terminal arrangement with us for your channel mix.
Digital inputsWT30i: 2 × 0–24 V · WT36i: 2 × 0–24 V · WT32i: 10 × 0–24 VThe WT32i is the digital-heavy card — 10 DI plus 8 outputs.
OutputsWT32i: 8 × relay / transistor · WT36i: 1 × relay, NO/COM · WT30i: no outputs listed in our product data — it is an input cardOur product data lists the WT32i outputs as relay / transistor. Confirm the output type you need with us at enquiry.
Pulse / counter inputsWT30i: 2 × 32-bit counters (optional) · WT36i: 2 pulse inputs (optional) · WT32i: not listedOptional build variant — tell us at enquiry if you need flow or energy pulse counting.
WatchdogWT32i: configurable via Modbus. Not listed in our product data for the WT30i or WT36i.On the WT32i, output fail-safe behaviour is set over the bus rather than by DIP switch.
Interface and protocolRS485 / Modbus RTU — all three modelsModbus RTU only. No Ethernet, Wi-Fi, cellular, LoRa, MQTT or OPC UA on the card itself, and no ASCII command set.
Power input12–24 V DC — all three modelsStandard panel supply; same rail as most RS485 field devices.
MountingDIN-rail (listed as the WT30i form factor); DIN-rail kit listed as an accessory across all three modelsDesigned for the same rail as your breakers and PSU.
Signal types not offeredNo RTD, thermocouple or dedicated counter-module variants in the current rangeIf you need direct RTD or thermocouple input, our cards are not the answer — use a transmitter ahead of the analog input, or a module built for it.
Target applicationsFactory automation, industrial IoT, water monitoring, energy monitoring, building automationPer the application tagging in our own product catalogue, taken across all three models.
CertificationsNone listed in our product data for these three modelsAsk us what applies to your market before you specify the card into a certified assembly.
Isolation, operating temperature range, accuracy, resolution, sampling rate, surge/EFT/ESD ratingsNot published in our catalogue dataWe will not print a number we cannot back with a test record. Ask engineering and we will tell you what we have measured for your environment — and if your cabinet is genuinely harsh, we will say so.

When Advantech is the better choice

There are jobs where the honest recommendation is to buy the ADAM module, and this is the place we would rather be useful than persuasive. Start with the direct comparison, because that is where the decision actually gets made. Within RS-485 Modbus RTU itself, Advantech's ADAM-4000/4100 line covers signal types we do not build at all: RTD, thermocouple, dedicated counter and relay modules, alongside analog and digital.

If your panel needs a PT100 or a K-type wired straight into the module, we have no equivalent and you should buy theirs. They also publish a full performance and environmental specification on the current-generation parts where we publish none — the ADAM-4117, the modern 8-channel analog input module and the correct like-for-like comparison, is rated 16-bit, 100 samples/second summed, 3,000 VDC isolation, -40 to 85 °C operating range, 10~48 VDC input, with 4kV surge, 4kV EFT and 8kV ESD protection.

We do not publish resolution, sampling rate, isolation, accuracy or temperature figures for our cards, and we are not going to imply parity we have not measured. If the site is an unconditioned outdoor cabinet or a high-noise VFD panel, or if your specification demands those numbers printed on a datasheet today, use their current-generation module.

Advantech describes the line's rugged industrial-grade cases as designed for reliable operation in harsh environments, and on that line they publish the figures to go with it. Their modules also speak an ASCII command set alongside Modbus RTU, which matters if you have existing software written against it — ours do not.

And their register maps are already supported by essentially every SCADA and HMI package, so a generation of Indian instrumentation engineers can commission one with no learning curve at all; that is worth real project time. Beyond the head-to-head, Advantech is a publicly listed manufacturer (TWSE: 2395) with roughly US$2.27 billion in 2025 revenue and around 9,000 employees, which clears a formal supplier-risk assessment in a way no small manufacturer can match.

If your primary criterion is that the vendor will still exist and still ship this part in fifteen years, they are the safer answer and we will not pretend otherwise. Their remote I/O portfolio also spans topologies we simply do not offer: Ethernet modules with a Modbus/TCP server plus MQTT, SNMP, RESTful and HTTP and a built-in web page (ADAM-6000), daisy-chainable two-port Ethernet with auto-bypass so the chain survives a module losing power (ADAM-6200), native OPC UA straight from the module to SCADA with no protocol gateway in the panel (ADAM-6300), IP67 machine-mount PROFINET on M12 (ADAM-250PN), and wireless variants over Wi-Fi, LoRaWAN and NB-IoT/Cat-M1 (WISE-4000).

The ADAM-6000 range also runs standalone peer-to-peer and graphic condition logic on the module itself, which lets a small distributed interlock work with no PLC at all — a genuinely useful capability we have no equivalent for. Our cards are RS485 Modbus RTU only. Add to that a documented warranty position — two years parts and labour from the invoice date, extendable by purchase to a maximum of five years total, available up to 90 days after order entry — a mature configuration utility and class library covering 150-plus models under one tool, a public per-model archive of firmware, drivers, FAQs and manuals going back many editions, and worldwide self-serve stock through major authorised distributors including DigiKey, Mouser, TME and RS.

That last point is decisive if you export machines and your customer must be able to order an identical spare in their own country; we cannot match it. They also have an Indian entity in Bengaluru and named channel partners, so "no local support" is not a true statement about them. Where we compete is narrower and specific: rupee pricing with no forex or duty drift, a lead time we own because we build here, engineers you can reach in your working hours and put on site, customisation at Indian OEM volumes, and local content for tenders scored on it.

If those are the constraints binding your project, talk to us. If the constraints above are the binding ones, buy theirs. Advantech and ADAM are trademarks of Advantech Co., Ltd. Wiman is not affiliated with, endorsed by, sponsored by, or an authorised distributor of Advantech. Their product names are referenced here only to identify the products a buyer is comparing against, and every statement on this page about their range is drawn from their own published material.

Questions we get asked

Is a Wiman I/O card a drop-in replacement for an ADAM-4017 or similar module?

No, and we will not describe it as one. Our cards speak Modbus RTU only, so anything written against an ASCII command set will need changing, and the register map, terminal pinout and mounting are our own. What we will do is send you our full register map before you order, and — if you send us the exact model and configuration you are replacing — physically run the comparison on the bench and give you the written result. We only use the words "drop-in" when we can hand over that test record.

Which Wiman card should I look at if I need an 8-channel analog input module?

Start with the WT36i. Our product data lists it as 6 × 0–10 V and 6 × 0/4–20 mA, plus 2 digital inputs and one NO/COM relay output — ask us to confirm the exact terminal arrangement for the mix you need. If you need more analog channels than that, the usual answer is two cards on the same RS485 bus at different slave IDs; ask us to cost both options for your channel count. If you would rather have one card with your exact channel mix, tell us what it is — building a variant is normal work for us, not an exception.

Which card do I use for mostly digital I/O?

The WT32i. It carries 10 × 0–24 V digital inputs and 8 outputs listed as relay / transistor, and adds 2 × 0–10 V and 2 × 4–20 mA analog inputs so you do not need a second card for a couple of stray sensors. Confirm the output type you need with us at enquiry. Its watchdog is configurable over Modbus, so you decide what the outputs do if the master stops polling.

What software do I need to commission these?

None of ours specifically. They are standard Modbus RTU devices on RS485, so any Modbus master on any operating system will configure and read them — Linux edge gateway, Python script, browser tool or your existing SCADA. If you want tooling, our WIMNET Modbus Scanner does device scan, register sweep, byte-swap decode and raw RX/TX hex with timing, and there is a live demo of it on this site; ask us for the application itself. Our browser-based Modbus hex converter is free to use. There is no licence or dongle attached to the hardware.

Do these cards do Modbus TCP, MQTT or OPC UA?

Not on the card. The WT30i, WT36i and WT32i are RS485 Modbus RTU only — that is what our product data says and we will not imply otherwise. To get to Ethernet, a server or a broker, put a Wiman gateway or protocol converter on the same bus: that is the normal architecture and it also gives you logging and store-and-forward, which a plain I/O module does not have. If you specifically need Modbus/TCP or OPC UA spoken by the I/O module itself with nothing else in the panel, that is a case for an Ethernet-native module from a vendor who makes one.

What are the isolation, operating temperature, resolution and accuracy figures?

We do not publish them in our catalogue data, so we are not going to quote them on a comparison page. Ask us and we will tell you what we have actually measured, and for a specific installation we would rather discuss your cabinet temperature, your supply quality and what is switching nearby than trade datasheet numbers. If your environment genuinely needs a published wide-temperature, high-surge specification on paper today, we will tell you that too — and point you at a module that carries one.

Can you do RTD or thermocouple inputs?

Not directly. Our current range has no RTD or thermocouple variant, so a PT100 or a thermocouple needs a transmitter converting it to 4–20 mA or 0–10 V ahead of one of our analog inputs. If you want the sensor wired straight into the module, use a vendor who builds that module — Advantech's RS-485 line includes RTD and thermocouple models. If direct RTD input is something you would order in volume, tell us; it is a conversation about a new variant rather than something we can ship today.

Can you white-label the cards or change the firmware for our machine?

Yes, and at the order sizes an Indian machine builder or panel shop typically places. That covers your brand and part number on the front panel, a different channel mix, terminal arrangement changes to suit an existing loom, register addressing laid out to match a SCADA tag database you already have, and behavioural changes such as scaling, engineering-unit conversion or watchdog action. Send us the requirement through the enquiry form and an engineer will come back on whether it is a configuration change, a firmware build or a new layout.

What is the lead time and how is it quoted?

The cards are built in Chennai and quoted in INR, so there is no import clearance step, no inland freight from a port and no exchange-rate movement between the quotation and the purchase order. Ask us for the current position on your quantity and we will give you a date we are willing to be held to.

Is Wiman affiliated with Advantech?

No. Advantech and ADAM are trademarks of Advantech Co., Ltd. Wiman is not affiliated with, endorsed by, sponsored by, or an authorised distributor of Advantech. Their product names are referenced on this page only to identify the products a buyer is comparing against, and every statement here about their range is drawn from their own published material.

Where to go next

Tell us the site, the protocol and the quantity — we will tell you honestly whether we fit.Send an enquiry →

Advantech and ADAM are trademarks of Advantech Co., Ltd. All trademarks are the property of their respective owners. Wiman is not affiliated with, endorsed by or sponsored by Advantech. Comparisons describe our own products only; verify any third-party product against its current published datasheet before purchase.